Clinton (Gladstone) 2019 hourly air quality...
Period of operation: 1 January to 31 December 2019
Site location: Latitude: -23.8701; Longitude: 151.2216
AS/NZS 3580.1.1 site classification: Neighbourhood
AS/NZS 3580.1.1 compliance (pollutants): Complies fully
AS/NZS 3580.14 compliance (meteorology): Complies, except for:
- Wind, temperature, relative humidity, rainfall and barometric pressure sensors located 10 metres above ground level.
- Rainfall measured by acoustic sensor
Wind: Ultrasonic sensor
- Height above ground level: 10 metres.
- The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +10 degrees to the sensor output value.
Temperature: Capacitive ceramic sensor.
- Height above ground level: 10 metres.
Relative humidity: Capacitive thin film polymer sensor.
- Height above ground level: 10 metres.
Rainfall: Vaisala RAINCAP® precipitation sensor.
- Height above ground level: 10 metres.
Barometric pressure: Capacitive silicon sensor.
- Height above ground level: 10 metres.
Oxides of nitrogen: Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1
- Instrument output offset and/or scaled based on calibration and daily zero/span response data.
Sulfur dioxide: Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1
- Instrument output offset and/or scaled based on calibration and daily zero/span response data.
PM10/PM2.5 (until 27 March): Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-DF fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13
- The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter.
- Reported concentrations are uncorrected instrument output values.
- The reported PM10 and PM2.5 concentrations are calculated from running 1-hour average concentrations updated at six minute intervals.
- Negative hourly PM10/PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported.
PM10/PM2.5 (from 27 March): Scattered light spectrometry (TAPI Model 640X) operated in accordance with USEPA equivalence method designation requirements
- Reported concentrations are uncorrected instrument output values.
Visibility-reducing particles: Nephelometer operated in accordance with AS/NZS 3580.12.1
- Detector spectral response centred at 530 nm.
- Instrument output offset and/or scaled based on calibration and daily zero/span response data.
Source
This data file or API can be downloaded from:
https://www.data.qld.gov.au/dataset/827a95bc-7160-4510-9a75-b4b4d22042a6/resource/755996e0-4a83-4b77-a148-7aaa0d346d0e/download/clinton-aq-2019.csvResources
There are no views created for this resource yet.
Data Dictionary
Additional Information
Field | Value |
---|---|
Data last updated | April 10, 2025 |
Metadata last updated | May 5, 2025 |
Format | CSV |
License | cc-by-4 |
Ckan url | https://www.data.qld.gov.au |
Datastore active | True |
Datastore contains all records of source file | True |
Has views | False |
Hash | 8fbe3ab4733904bdb30bbe0b63ae01a5 |
Id | 755996e0-4a83-4b77-a148-7aaa0d346d0e |
Ignore hash | False |
Mimetype | text/csv |
Original url | https://www.data.qld.gov.au/dataset/827a95bc-7160-4510-9a75-b4b4d22042a6/resource/755996e0-4a83-4b77-a148-7aaa0d346d0e/download/clinton-aq-2019.csv |
Package id | 827a95bc-7160-4510-9a75-b4b4d22042a6 |
Position | 8 |
Resource id | 755996e0-4a83-4b77-a148-7aaa0d346d0e |
State | active |
Task created | 2025-04-02 00:48:59.670278 |
Zip extract | False |
Size | Unknown |
ID | 755996e0-4a83-4b77-a148-7aaa0d346d0e |
Harvested | True |
Package ID | 827a95bc-7160-4510-9a75-b4b4d22042a6 |
State | active |