North Maclean (South East Queensland) 2012...

Air Quality Monitoring - 2012

Created 04/05/2025

Updated 04/05/2025

Period of operation: 1 January to 31 December 2012

  • Monitoring of rainfall and barometric pressure commenced 1 December 2012

Site location: Latitude: -27.7708; Longitude: 153.0300
AS/NZS 3580.1.1:2007 site classification: Background
AS/NZS 3580.1.1:2007 compliance (pollutants): Complies fully
AS/NZS 3580.14—2011 compliance (meteorology): Complies with the exception of the following:

  • Temperature and relative humidity sensors located at a height of 10 metres above ground level

Wind: Ultrasonic sensor

  • Height above ground level: 10 metres
  • The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.

Temperature: Capacitive ceramic sensor

  • Height above ground level: 10 metres (from 1 December)

Relative humidity: Capacitive thin film polymer sensor

  • Height above ground level: 10 metres (from 1 December)

Rainfall: Vaisala RAINCAP® precipitation sensor

  • Height above ground level: 10 metres

Barometric pressure: Capacitive silicon sensor

  • Height above ground level: 10 metres

Ozone: UV absorption analyser operated in accordance with AS/NZS 3580.6.1—2010

  • Instrument output offset and/or scaled based on calibration and daily zero/span response data

Oxides of nitrogen: Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1—2010

  • Instrument output offset and/or scaled based on calibration and daily zero/span response data

Source

This data file or API can be downloaded from:

https://data.des.qld.gov.au/__data/assets/file/0026/83582/northmaclean-aq-2012.csv