Townsville Lennon Drive (Townsville) 2023...

Air Quality Monitoring - 2023

Created 04/05/2025

Updated 04/05/2025

Industry-operated monitoring site: Data presented as received by Queensland Government
Period of operation: 1 January to 31 December 2023
Site location: Latitude: -19.2589; Longitude: 146.8264
AS/NZS 3580.1.1 site classification: Peak (port operations)
AS/NZS 3580.1.1 compliance (pollutants): Complies fully
AS/NZS 3580.14 compliance (meteorology): Complies, except for:

  • Temperature and relative humidity sensors located 10 metres above ground level.

Wind: Ultrasonic sensor

  • Height above ground level: 10 metres.

Temperature: Negative temperature coefficient (NTC) thermistor

  • Height above ground level: 10 metres.

Relative humidity: Capacitive thin film polymer sensor

  • Height above ground level: 10 metres.

Barometric pressure: MEMS capacitive pressure sensor

PM10: Scattered light spectrometry (TAPI Model 640X) operated in accordance with USEPA equivalence method designation requirements

  • Reported concentrations are uncorrected instrument output values.

TSP: Tapered Element Oscillating Microbalance (TEOM) Model 1405 fitted with TSP inlet and operated in accordance with AS/NZS 3580.9.16 (excluding FDMS requirements)

  • Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.
  • Reported concentrations are uncorrected instrument output values.
  • Negative hourly TSP concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3.

Source

This data file or API can be downloaded from:

https://www.data.qld.gov.au/dataset/1e627b1a-5ac4-440e-bb78-7c7f2537b2de/resource/45731630-8700-4821-b245-1c3a824739e5/download/townsvillelennondrive-aq-2023.csv