Townsville Port (Townsville) 2009 hourly air...

Air Quality Monitoring - 2009

Created 24/02/2025

Updated 24/02/2025

Industry-operated monitoring site: Data received from industry validated by Queensland Government
Period of operation: 1 January to 31 December 2009
Region: Townsville
Site location: Latitude: -19.2502; Longitude: 146.8304
AS/NZS 3580.1.1 site classification: Peak (port operations)
AS/NZS 3580.1.1 compliance (pollutants): Complies fully
AS/NZS 3580.14 compliance (meteorology): Complies fully
Wind: Mechanical propeller and vane sensor

  • Height above ground level: 10 metres.

PM10: Tapered Element Oscillating Balance (TEOM) Model 1400AB operated in accordance with AS 3580.9.8

  • Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.
  • Instrument output values are adjusted in accordance with US EPA equivalence designation method EQPM-1090-079 requirements (scaled by 1.03, offset by +3.0).
  • After adjustment, negative hourly PM10 concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3.

Source

This data file or API can be downloaded from:

https://www.data.qld.gov.au/dataset/bf767255-f782-457c-83b8-2dd0c193149a/resource/01b771fb-2831-4c0a-8caf-11c9aa9adc86/download/townsvilleport-aq-2009.csv