Auckland Point (Gladstone) 2009 hourly air...

Air Quality Monitoring - 2009

Created 24/02/2025

Updated 24/02/2025

Period of operation: 28 May (site established) to 31 December 2009 (long path instrument operational from 22 June)
Region: Gladstone
Site location: Latitude: -23.8351; Longitude: 151.2539
AS/NZS 3580.1.1 site classification: Neighbourhood
AS/NZS 3580.1.1 compliance (pollutants): Complies, except for:

  • DOAS light path between 4 metres and 25 metres above ground level

AS/NZS 3580.14 compliance (meteorology): Complies, except for:

  • Located on southern side of slope below a ridge
  • Trees within 20 metres of the monitoring site

Wind: Ultrasonic sensor

  • Height above ground level: 10 metres
  • The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +10 degrees to the sensor output value.

Ozone, nitrogen dioxide, sulfur dioxide, benzene, toluene, xylenes (total), formaldehyde: Differential Optical Absorption Spectroscopy (DOAS) analyser operated in accordance with AS/NZS 3580.15

  • Value is average concentration over 680 metre light path running north-south from ‑23.8351, 151.2539 to -23.8409,151.2550
  • Instrument output offset and/or scaled based on instrument calibration data

Source

This data file or API can be downloaded from:

https://www.data.qld.gov.au/dataset/bf767255-f782-457c-83b8-2dd0c193149a/resource/2e7b0a8b-70bd-4f85-8433-1bd1c25680bc/download/aucklandpoint-aq-2009.csv