Targinie (Gladstone) 2010 hourly air quality...
Period of operation: 1 January to 31 December 2010
Site location: Latitude: -23.7743; Longitude: 151.1060
AS/NZS 3580.1.1 site classification: Background
AS/NZS 3580.1.1 compliance (pollutants): Complies fully
AS/NZS 3580.14 compliance (meteorology): Complies, except for:
- Trees within 15 metres north west of the monitoring site.
- Temperature and relative humidity sensors located 10 metres above ground level.
- Rainfall measured by acoustic sensor.
Wind: Ultrasonic sensor
- Height above ground level: 10 metres.
- The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +10 degrees to the sensor output value.
Temperature: Capacitive ceramic sensor
- Height above ground level: 10 metres.
Relative humidity: Capacitive thin film polymer sensor
- Height above ground level: 10 metres.
Rainfall: Vaisala RAINCAP® precipitation sensor
- Height above ground level: 10 metres.
Barometric pressure: Capacitive silicon sensor
- Height above ground level: 10 metres.
Oxides of nitrogen: Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1
- Instrument output offset and/or scaled based on calibration and daily zero/span response data.
Sulfur dioxide: Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1
- Instrument output offset and/or scaled based on calibration and daily zero/span response data.
PM10/PM2.5: Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-DF fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13
- The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter.
- Reported concentrations are uncorrected instrument output values.
- Negative hourly PM10/PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported.
Visibility-reducing particles: Nephelometer operated in accordance with AS/NZS 3580.12.1
- Detector spectral response centred at 530 nm.
- Instrument output offset and/or scaled based on calibration and daily zero/span response data.
Source
This data file or API can be downloaded from:
https://data.des.qld.gov.au/__data/assets/file/0022/84028/targinie-aq-2010.csvResources
There are no views created for this resource yet.
Data Dictionary
Additional Information
Field | Value |
---|---|
Data last updated | April 2, 2025 |
Metadata last updated | April 8, 2025 |
Format | CSV |
License | cc-by-4 |
Ckan url | https://www.data.qld.gov.au |
Datastore active | True |
Datastore contains all records of source file | True |
Has views | False |
Hash | bbf9a67143372a2e91920b98fa9f401a |
Id | 17c46ab9-8f01-409c-9ed6-810b2fa67459 |
Ignore hash | False |
Mimetype | text/csv |
Original url | https://data.des.qld.gov.au/__data/assets/file/0022/84028/targinie-aq-2010.csv |
Package id | b4644687-7d7d-47ba-92f3-76ef8c73d6cb |
Position | 24 |
Resource id | 17c46ab9-8f01-409c-9ed6-810b2fa67459 |
State | active |
Task created | 2025-04-02 07:47:38.185092 |
Zip extract | False |
Size | Unknown |
ID | 17c46ab9-8f01-409c-9ed6-810b2fa67459 |
Harvested | True |
Package ID | b4644687-7d7d-47ba-92f3-76ef8c73d6cb |
State | active |