For the AusAEM Year 1 survey an inertial measurement unit (IMU) was installed for the first time on the TEMPEST receiver bird to measure its orientation and to augment GPS derived positioning of the receiver. This has given us the opportunity to develop better quality control and calibration procedures, which would otherwise not be possible. Theoretical modelling of the primary field on high altitude zero-lines, using the full position/orientation information, revealed discrepancies between observed and modelled data. It alerted us to time-lag parallaxes between EM and bird position/orientation data, some spurious IMU data on many pre-flight zero-lines, and a coordinate system sign convention inconsistency. The modelling also revealed systematic differences that we could attribute to the calibration of the receiver pitch and EM data scaling. We developed an inversion algorithm to solve for a receiver pitch offset and an EM scaling calibration parameter, for each zero-line, which minimised the systematic discrepancies. It eventuated that the calibration parameters fell into five distinct populations explicable by significant equipment changes. This gave us the confidence to use the medians of these populations as parameters to calibrate the data. The work shows the value of the new receiver bird orientation data and the importance of accurate IMU calibration after any modification. It shows the practical utility of quantitative modelling in the quality control workflow. It also demonstrates how modelling and inversion procedure can be used to successfully diagnose calibration issues in fixed-wing AEM data. Presented at the 2019 Australasian Exploration Geoscience Conference

Files and APIs

Tags

Additional Info

Field Value
Title AusAEM Year 1: Some aspects of quality control and calibration
Language eng
Licence notspecified
Landing Page https://devweb.dga.links.com.au/data/dataset/8047302d-9ff5-4e96-9072-27cad8eb1f65
Contact Point
Geoscience Australia
clientservices@ga.gov.au
Reference Period 08/04/2019
Geospatial Coverage {"type": "Polygon", "coordinates": [[[112.0, -44.0], [154.0, -44.0], [154.0, -9.0], [112.0, -9.0], [112.0, -44.0]]]}
Data Portal data.gov.au

Data Source

This dataset was originally found on data.gov.au "AusAEM Year 1: Some aspects of quality control and calibration". Please visit the source to access the original metadata of the dataset:
https://devweb.dga.links.com.au/data/dataset/ausaem-year-1-some-aspects-of-quality-control-and-calibration

No duplicate datasets found.