Clinton (Gladstone) 2015 hourly air quality...
Period of operation: 1 January to 31 December 2015
Site location: Latitude: -23.8701; Longitude: 151.2216
AS/NZS 3580.1.1:2007 site classification: Neighbourhood
AS/NZS 3580.1.1:2007 compliance (pollutants): Complies fully
AS/NZS 3580.14:2011 compliance (meteorology): Complies, except for:
- Temperature and relative humidity sensors located 10 metres above ground level.
- Rainfall mesured by acoustic sensor
Wind: Ultrasonic sensor
- Height above ground level: 10 metres.
- The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +10 degrees to the sensor output value.
Temperature: Capacitive ceramic sensor.
- Height above ground level: 10 metres.
Relative humidity: Capacitive thin film polymer sensor.
- Height above ground level: 10 metres.
Rainfall: Vaisala RAINCAP® precipitation sensor.
- Height above ground level: 10 metres.
Barometric pressure: Capacitive silicon sensor.
- Height above ground level: 10 metres.
Oxides of nitrogen: Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1
- Instrument output offset and/or scaled based on calibration and daily zero/span response data.
Sulfur dioxide: Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1
- Instrument output offset and/or scaled based on calibration and daily zero/span response data.
PM10/PM2.5: Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-DF fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13
- The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter.
- Reported concentrations are uncorrected instrument output values.
- The reported PM10 and PM2.5 concentrations are calculated from running 1-hour average concentrations updated at six minute intervals.
- Negative hourly PM10/PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported.
Visibility-reducing particles: Nephelometer operated in accordance with AS/NZS 3580.12.1
- Detector spectral response centred at 530 nm.
- Instrument output offset and/or scaled based on calibration and daily zero/span response data.
Source
This data file or API can be downloaded from:
https://data.des.qld.gov.au/__data/assets/file/0025/83932/clinton-aq-2015.csvResources
There are no views created for this resource yet.
Data Dictionary
Additional Information
Field | Value |
---|---|
Data last updated | April 2, 2025 |
Metadata last updated | May 4, 2025 |
Format | CSV |
License | cc-by-4 |
Datastore active | True |
Datastore contains all records of source file | False |
Has views | False |
Hash | e4337f71034c47ac755b179844ea185b |
Id | 8bea24b6-a22a-4435-a52b-d5041133ac89 |
Mimetype | text/csv |
Package id | 244cef2b-420a-4d5e-9f3e-f932da7afa0d |
Position | 8 |
State | active |
Zip extract | False |
Size | Unknown |
ID | 8bea24b6-a22a-4435-a52b-d5041133ac89 |
Harvested | True |
Package ID | 244cef2b-420a-4d5e-9f3e-f932da7afa0d |
State | active |