Pimlico (Townsville) 2015 hourly air quality...
Period of operation: 1 January to 31 December 2015
Site location: Latitude: -19.2871; Longitude: 146.7813
AS/NZS 3580.1.1 site classification: Neighbourhood
AS/NZS 3580.1.1 compliance (pollutants): Complies fully
AS/NZS 3580.14 compliance (meteorology): Complies, except for:
- Isolated trees within 20 metres of the monitoring site.
- Three storey building located within 30 metres south of the monitoring site.
Wind: Ultrasonic sensor
- Height above ground level: 10 metres.
- The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +8 degrees to the sensor output value.
Temperature: Capacitive ceramic sensor
- Sensor mounted in non-aspirated radiation shield 4 metres above ground level – under still conditions reported temperature can be higher than actual.
Ozone: UV absorption analyser operated in accordance with AS/NZS 3580.6.1
- Instrument output offset and/or scaled based on calibration and daily zero/span response data.
Oxides of nitrogen: Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1
- Instrument output offset and/or scaled based on calibration and daily zero/span response data.
Sulfur dioxide: Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1
- Instrument output offset and/or scaled based on calibration and daily zero/span response data.
PM10 (1 January to 19 May): Tapered Element Oscillating Balance (TEOM) Model 1400AB operated in accordance with AS 3580.9.8
- Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.
- Instrument output values are adjusted in accordance with US EPA equivalence designation method EQPM-1090-079 requirements (scaled by 1.03, offset by +3.0).
- After adjustment, negative hourly PM10 concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3.
PM10 (19 May to 31 December): Tapered Element Oscillating Balance (TEOM) Model 1405 operated in accordance with AS/NZS 3580.9.13, excepting FDMS requirements
- Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.
- Reported concentrations are uncorrected instrument output values.
- Negative hourly PM10 concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3.
Source
This data file or API can be downloaded from:
https://data.des.qld.gov.au/__data/assets/file/0036/83997/pimlico-aq-2015.csvResources
There are no views created for this resource yet.
Data Dictionary
Additional Information
Field | Value |
---|---|
Data last updated | April 2, 2025 |
Metadata last updated | May 4, 2025 |
Format | CSV |
License | cc-by-4 |
Datastore active | True |
Datastore contains all records of source file | False |
Has views | False |
Hash | 1c7e3291e5b281d255a692ea1f6bec32 |
Id | ccca3a4e-c44e-4190-8a85-f27286820ab1 |
Mimetype | text/csv |
Package id | 244cef2b-420a-4d5e-9f3e-f932da7afa0d |
Position | 24 |
State | active |
Zip extract | False |
Size | Unknown |
ID | ccca3a4e-c44e-4190-8a85-f27286820ab1 |
Harvested | True |
Package ID | 244cef2b-420a-4d5e-9f3e-f932da7afa0d |
State | active |