Stuart (Townsville) 2017 hourly air quality...

Air Quality Monitoring - 2017

Created 04/05/2025

Updated 04/05/2025

Industry-operated monitoring site: Raw data received from industry validated by Queensland Government
Period of operation: 1 January to 31 December 2017
Site location: Latitude: -19.3212; Longitude: 146.8422
AS/NZS 3580.1.1 site classification: Neighbourhood
AS/NZS 3580.1.1 compliance (pollutants): Complies fully
AS/NZS 3580.14: compliance (meteorology): Complies fully, except for:

  • Temperature and relative humidity sensors located 10 metres above ground level.
  • Rainfall measured by acoustic sensor.

Temperature: Capacitive ceramic sensor

  • Height above ground level: 10 metres.

Relative humidity: Capacitive thin film polymer sensor

  • Height above ground level: 10 metres.

Rainfall: Vaisala RAINCAP® precipitation sensor.

  • Height above ground level: 10 metres.

Barometric pressure: Capacitive silicon sensor.

  • Height above ground level: 10 metres.

Sulfur dioxide: Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1.

  • Instrument output offset and/or scaled based on calibration and daily zero/span response data.