Townsville Coast Guard (Townsville) 2017...
Joint Queensland Government / industry-operated monitoring site: Data validation conducted by the Queensland Government.
Period of operation: 1 January to 31 December 2017
Site location Latitude: -19.2542; Longitude: 146.8257
AS/NZS 3580.1.1 site classification: Peak (port operations)
AS/NZS 3580.1.1 compliance (pollutants): Complies fully
AS/NZS 3580.14 compliance (meteorology): Complies, except for:
- Trees within 5 metres to the west of the industry/joint monitoring station (no obstructions in direction of port operations).
- Monitoring stations located on asphalt surface.
- Temperature (from 7 November) and relative humidity sensors located 10 metres above ground level.
- Rainfall measured by acoustic sensor.
Wind sensor: Ultrasonic sensor
- Height above ground level: 10 metres.
Temperature (to 6 November): Capacitive ceramic sensor
Temperature (from 7 November): Negative temperature coefficient (NTC) thermistor
- Height above ground level: 10 metres.
Relative humidity (from 7 November): Capacitive thin film polymer sensor
- Height above ground level: 10 metres.
Rainfall (from 7 November): Doppler radar
- Height above ground level: 10 metres.
Barometric pressure (from 7 November): MEMS capacitive pressure sensor
- Height above ground level: 10 metres.
Solar radiation (from 7 November): Thermopile
- Height above ground level: 10 metres.
PM10 (to 24 March): Tapered Element Oscillating Balance (TEOM) Model 1400AB operated in accordance with AS 3580.9.8
- Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.
- Instrument output values are adjusted in accordance with US EPA equivalence designation method EQPM-1090-079 requirements (scaled by 1.03, offset by +3.0).
- After adjustment, negative hourly PM10 concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3.
PM10 (from 7 November): Scattered light spectrometry (TAPI Model 640X) operated in accordance with USEPA equivalence method designation requirements
- Reported concentrations are uncorrected instrument output values.
TSP: Tapered Element Oscillating Microbalance (TEOM) Model 1405 fitted with TSP inlet and operated in accordance with AS/NZS 3580.9.16 (excluding FDMS requirements)
- Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.
- Reported concentrations are uncorrected instrument output values.
- Negative hourly TSP concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3.
Source
This data file or API can be downloaded from:
https://www.data.qld.gov.au/dataset/4dcbe485-760a-4901-9757-d220c5fbd072/resource/aa73f1e7-31f3-466a-8512-ed88b698b881/download/townsvillecoastguardaq2017.csvResources
There are no views created for this resource yet.
Data Dictionary
Additional Information
Field | Value |
---|---|
Data last updated | April 2, 2025 |
Metadata last updated | May 4, 2025 |
Format | CSV |
License | cc-by-4 |
Datastore active | True |
Datastore contains all records of source file | False |
Has views | False |
Hash | 39898c9f5a8c07d52944f88aa0f45d1e |
Id | aa73f1e7-31f3-466a-8512-ed88b698b881 |
Mimetype | text/csv |
Package id | 4dcbe485-760a-4901-9757-d220c5fbd072 |
Position | 33 |
State | active |
Zip extract | False |
Size | Unknown |
ID | aa73f1e7-31f3-466a-8512-ed88b698b881 |
Harvested | True |
Package ID | 4dcbe485-760a-4901-9757-d220c5fbd072 |
State | active |