North Ward (Townsville) 2017 hourly air...

Air Quality Monitoring - 2017

Created 04/05/2025

Updated 04/05/2025

Period of operation: 6 December (site established) to 31 December 2017
Site location Latitude: -19.2509; Longitude: 146.8073
AS/NZS 3580.1.1 site classification: Neighbourhood
AS/NZS 3580.1.1 compliance (pollutants): Complies, except for:

  • Isolated trees above height of inlet within 10 metres west of the monitoring site.

AS/NZS 3580.14 compliance (meteorology): Complies, except for:

  • Isolated trees within 10 metres west of the monitoring site.
  • Temperature and relative humidity sensors located 10 metres above ground level.
  • Rainfall measured by acoustic sensor.

Wind sensor: Ultrasonic sensor

  • Height above ground level: 10 metres.
  • The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +8 degrees to the sensor output value.

Temperature: Capacitive ceramic sensor

  • Height above ground level: 10 metres.

Relative humidity: Capacitive thin film polymer sensor

  • Height above ground level: 10 metres.

Rainfall: Vaisala RAINCAP® precipitation sensor

  • Height above ground level: 10 metres.

Barometric pressure: Capacitive silicon sensor

  • Height above ground level: 10 metres.

Oxides of nitrogen: Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1

  • Instrument output offset and/or scaled based on calibration and daily zero/span response data.

Sulfur dioxide: Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1

  • Instrument output offset and/or scaled based on calibration and daily zero/span response data.

PM10/PM2.5: Scattered light spectrometry (TAPI Model 640X) operated in accordance with USEPA equivalence method designation requirements

  • Reported concentrations are uncorrected instrument output values.

Visibility-reducing particles: Nephelometer operated in accordance with AS/NZS 3580.12.1

  • Detector spectral response centred at 520 nm.
  • Instrument output offset and/or scaled based on calibration and daily zero/span response data.

Updated 02/10/2019: North Ward PM10 and PM2.5 measurements corrected to standard conditions of 0°C and 1013.25kPa

Source

This data file or API can be downloaded from:

https://www.data.qld.gov.au/dataset/4dcbe485-760a-4901-9757-d220c5fbd072/resource/11aa09c4-13c3-4af0-b56e-10721be1577d/download/northward-aq-2017.csv