Lytton (South East Queensland) 2017 hourly air...

Air Quality Monitoring - 2017

Created 04/05/2025

Updated 20/05/2025

Industry-operated monitoring site: Data presented as received by Queensland Government
Period of operation: 1 January to 31 December 2017
Site location: Latitude: -27.4065; Longitude: 153.1527
AS/NZS 3580.1.1 site classification: Peak (industry) AS/NZS 3580.1.1 compliance (pollutants): Complies fully
AS/NZS 3580.14 compliance (meteorology) : Complies, except for:

  • Temperature and relative humidity sensors located 10 metres above ground level.
  • Rainfall measured by acoustic sensor.

Wind sensor: Ultrasonic sensor

  • Height above ground level: 10 metres.

Temperature: Capacitive ceramic sensor

  • Height above ground level: 10 metres.

Relative humidity: Capacitive thin film polymer sensor

  • Height above ground level: 10 metres.

Rainfall: Vaisala RAINCAP® precipitation sensor.

  • Height above ground level: 10 metres.

Barometric pressure: Capacitive silicon sensor.

  • Height above ground level: 10 metres.

Sulfur dioxide: Ultraviolet fluorescence analyser operated in accordance with AS 3580.4.1
PM10/PM2.5: Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-D operated in accordance with AS/NZS 3580.9.13 (excluding FDMS requirements)

  • Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.
  • Reported concentrations are uncorrected instrument output values.
  • Negative hourly PM10/PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported.

Source

This data file or API can be downloaded from:

https://www.data.qld.gov.au/dataset/4dcbe485-760a-4901-9757-d220c5fbd072/resource/8f6bc380-1a5f-4fc2-82bf-3615136b532a/download/lyttonaq2017.csv