Southport (South East Queensland) 2020 hourly...

Air Quality Monitoring - 2020

Created 24/02/2025

Updated 24/02/2025

Period of operation: 1 January to 31 December 2020
Site location: Latitude: -27.9612; Longitude: 153.4024
AS/NZS 3580.1.1 site classification: Neighbourhood
AS/NZS 3580.1.1 compliance (pollutants): Complies, except for:

  • Buildings below height of inlet within 5 metres north and east of the monitoring site
  • Isolated trees above height of inlet within 20 metres south of the monitoring site

AS/NZS 3580.14 compliance (meteorology): Complies, except for:

  • Isolated trees within 20 metres south of the monitoring site.
  • Temperature and relative humidity sensors located 10 metres above ground level.
  • Rainfall measured by acoustic sensor.

Wind: Ultrasonic sensor

  • Height above ground level: 10 metres.
  • The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.

Temperature: Capacitive ceramic sensor

  • Height above ground level: 10 metres.

Relative humidity: Capacitive thin film polymer sensor

  • Height above ground level: 10 metres.

Rainfall: Vaisala RAINCAP® precipitation sensor

  • Height above ground level: 10 metres.

Barometric pressure: Capacitive silicon sensor

  • Height above ground level: 10 metres.

Ozone: UV absorption analyser operated in accordance with AS/NZS 3580.6.1

  • Instrument output offset and/or scaled based on calibration and daily zero/span response data.

Oxides of nitrogen: Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1

  • Instrument output offset and/or scaled based on calibration and daily zero/span response data.

PM10/PM2.5: Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-DF fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13

  • The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter.
  • Reported concentrations are uncorrected instrument output values.
  • The reported PM10 and PM2.5 concentrations are calculated from running 1-hour average concentrations updated at six minute intervals.
  • Negative hourly PM10/PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported.

Source

This data file or API can be downloaded from:

https://www.data.qld.gov.au/dataset/e732d13e-6be1-4f69-9266-db25998e9f2c/resource/2046d2c0-f7ab-460c-950a-d9285d5aab40/download/southport-aq-2020.csv