Rocklea (South East Queensland) 2020 hourly...
Period of operation: 1 January to 31 December 2020
Site location: Latitude: -27.5358; Longitude: 152.9934
AS/NZS 3580.1.1 site classification: Neighbourhood
AS/NZS 3580.1.1 compliance (pollutants): Complies, except for:
- Isolated trees above height of inlet within 10 metres west of the monitoring site.
AS/NZS 3580.14 compliance (meteorology): Complies, except for:
- Isolated trees within 10 metres west of the monitoring site.
- Temperature and relative humidity sensors located 10 metres above ground level.
- Rainfall measured by acoustic sensor.
Wind: Ultrasonic sensor
- Height above ground level: 10 metres.
- The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.
Temperature: Capacitive ceramic sensor
- Height above ground level: 10 metres.
Relative humidity: Capacitive thin film polymer sensor
- Height above ground level: 10 metres.
Rainfall: Vaisala RAINCAP® precipitation sensor.
- Height above ground level: 10 metres.
Barometric pressure: Capacitive silicon sensor.
- Height above ground level: 10 metres.
Solar radiation: Pyranometer
Ozone: UV absorption analyser operated in accordance with AS/NZS 3580.6.1
- Instrument output offset and/or scaled based on calibration and daily zero/span response data.
Oxides of nitrogen: Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1
- Instrument output offset and/or scaled based on calibration and daily zero/span response data.
PM10/PM2.5: Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-DF fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13
- The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter.
- Reported concentrations are uncorrected instrument output values.
- The reported PM10 and PM2.5 concentrations are calculated from running 1-hour average concentrations updated at six minute intervals.
- Negative hourly PM10/PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported.
Visibility-reducing particles: Nephelometer operated in accordance with AS/NZS 3580.12.1
- Detector spectral response centred at 520 nm.
- Instrument output offset and/or scaled based on calibration and daily zero/span response data.
Source
This data file or API can be downloaded from:
https://www.data.qld.gov.au/dataset/e732d13e-6be1-4f69-9266-db25998e9f2c/resource/8b728c76-6e4b-42fd-8295-c235be928949/download/rocklea-aq-2020.csvResources
There are no views created for this resource yet.
Data Dictionary
Additional Information
Field | Value |
---|---|
Data last updated | November 9, 2021 |
Metadata last updated | February 24, 2025 |
Format | CSV |
License | cc-by-4 |
Ckan url | https://www.data.qld.gov.au |
Datastore active | True |
Datastore contains all records of source file | True |
Has views | False |
Hash | 404731e7f7dd8efdfdb3f192245a36c4 |
Id | 8b728c76-6e4b-42fd-8295-c235be928949 |
Ignore hash | False |
Mimetype | text/csv |
Original url | https://www.data.qld.gov.au/dataset/e732d13e-6be1-4f69-9266-db25998e9f2c/resource/8b728c76-6e4b-42fd-8295-c235be928949/download/rocklea-aq-2020.csv |
Package id | e732d13e-6be1-4f69-9266-db25998e9f2c |
Position | 30 |
Resource id | 8b728c76-6e4b-42fd-8295-c235be928949 |
Size | 777.5 KiB |
State | active |
Task created | 2021-11-09 06:30:27.916268 |
Zip extract | False |
Size | Unknown |
ID | 8b728c76-6e4b-42fd-8295-c235be928949 |
Harvested | True |
Package ID | e732d13e-6be1-4f69-9266-db25998e9f2c |
State | Archived |