Townsville Environment Park (Townsville) 2020...

Air Quality Monitoring - 2020

Created 24/02/2025

Updated 24/02/2025

Industry-operated monitoring site: Data presented as received by Queensland Government
Period of operation: 1 January to 31 December 2020
Site location: Latitude: -19.2631; Longitude: 146.8308
AS/NZS 3580.1.1 site classification: Peak (port operations)
AS/NZS 3580.1.1 compliance (pollutants): Complies fully
AS/NZS 3580.14 compliance (meteorology): Complies, except for:

  • Temperature and relative humidity sensors located 10 metres above ground level.
  • Rainfall measured by acoustic sensor.

Wind: Ultrasonic sensor

  • Height above ground level: 10 metres.

Temperature: Negative temperature coefficient (NTC) thermistor

  • Height above ground level: 10 metres.

Relative humidity: Capacitive thin film polymer sensor

  • Height above ground level: 10 metres.

Rainfall: Doppler radar
Barometric pressure: MEMS capacitive pressure sensor
Solar radiation: Thermopile
PM10: Scattered light spectrometry (TAPI Model 640X) operated in accordance with USEPA equivalence method designation requirements

  • Reported concentrations are uncorrected instrument output values.

Source

This data file or API can be downloaded from:

https://www.data.qld.gov.au/dataset/e732d13e-6be1-4f69-9266-db25998e9f2c/resource/226c47c4-28ad-427a-a803-1a00db0dc8bd/download/townsvilleenvironmentpark-aq-2020.csv