Rocklea (Brisbane) 2011 hourly air quality and...
Period of operation: 1 January to 11 January 2011 (site offline due to flood damage)
- Monitoring site damaged by severe flooding and offline for remainder of year awaiting replacement monitoring station infrastructure
Site location: Latitude: -27.5358; Longitude: 152.9934
AS/NZS 3580.1.1:2007 site classification: Neighbourhood
AS/NZS 3580.1.1:2007 compliance (pollutants): Complies with the exception of the following:
- Isolated trees above height of inlet within 10 metres to the west of the monitoring site
AS/NZS 3580.14—2011 compliance (meteorology): Complies with the exception of the following:
- Temperature and relative humidity sensors located at a height of 10 metres above ground level
Wind: Ultrasonic sensor
- Height above ground level: 10 metres
- The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.
Temperature: Platinum resistance sensor
Relative humidity: Capacitive thin film polymer sensor
Rainfall: Tipping bucket gauge
Solar radiation: Pyranometer
Ozone: UV absorption analyser operated in accordance with AS/NZS 3580.6.1—2010
- Instrument output offset and/or scaled based on calibration and daily zero/span response data
Oxides of nitrogen: Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1—2010
- Instrument output offset and/or scaled based on calibration and daily zero/span response data
PM10 / PM2.5: Dichotomous Tapered Element Oscillating Balance (TEOM) fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13—2013
- The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter.
- Reported concentrations are uncorrected instrument output values.
- Negative hourly PM10 / PM2.5 concentrations down to -5 µg/m3 resulting from instrument noise at low particle concentrations are reported.
Visibility-reducing particles: Nephelometer operated in accordance with AS/NZS 3580.12.1:2001
- Detector spectral response centred at 525 nm.
- Instrument output offset and/or scaled based on calibration and daily zero/span response data
Source
This data file or API can be downloaded from:
https://data.des.qld.gov.au/__data/assets/file/0024/83823/rocklea-aq-2011.csvResources
There are no views created for this resource yet.
Data Dictionary
Additional Information
Field | Value |
---|---|
Data last updated | April 2, 2025 |
Metadata last updated | May 5, 2025 |
Format | CSV |
License | cc-by-4 |
Ckan url | https://www.data.qld.gov.au |
Datastore active | True |
Datastore contains all records of source file | True |
Has views | False |
Hash | 95976de64e2d43a1bdca090b2f83ffb0 |
Id | 2e5573df-3581-4ea5-ac09-5f794ffeaf97 |
Ignore hash | False |
Mimetype | text/csv |
Original url | https://data.des.qld.gov.au/__data/assets/file/0024/83823/rocklea-aq-2011.csv |
Package id | 94ae85af-a62b-4ae4-a86b-631fb9cc4af5 |
Position | 22 |
Resource id | 2e5573df-3581-4ea5-ac09-5f794ffeaf97 |
Resource type | file |
State | active |
Task created | 2025-04-02 07:13:46.050356 |
Zip extract | False |
Size | Unknown |
ID | 2e5573df-3581-4ea5-ac09-5f794ffeaf97 |
Harvested | True |
Package ID | 94ae85af-a62b-4ae4-a86b-631fb9cc4af5 |
State | active |