Lutwyche (Brisbane) 2011 hourly air quality...

Air Quality Monitoring - 2011

Created 05/05/2025

Updated 05/05/2025

Period of operation: 27 April (site established) to 31 December 2011
Site location: Latitude: -27.4166; Longitude: 153.0376
AS/NZS 3580.1.1:2007: Peak (roadway construction works)
AS/NZS 3580.1.1:2007 compliance (pollutants): Complies with the exception of the following:

  • Building higher than inlet within 20 metres S of monitoring site

AS/NZS 3580.14—2011 compliance (meteorology): Complies with the exception of the following:

  • Building higher than wind sensor located within 20 metres S of monitoring site
  • Monitoring shelter located on asphalted surface

Wind: Ultrasonic sensor

  • Height above ground level: 6 metres
  • The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.

Temperature: Capacitive ceramic sensor

  • Height above ground level: 10 metres

Relative humidity: Capacitive thin film polymer sensor

  • Height above ground level: 10 metres

PM10 / PM2.5: Dichotomous Tapered Element Oscillating Balance (TEOM) fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13—2013

  • The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter.
  • Reported concentrations are uncorrected instrument output values.
  • Negative hourly PM10 / PM2.5 concentrations down to -5 µg/m3 resulting from instrument noise at low particle concentrations are reported.

Source

This data file or API can be downloaded from:

https://data.des.qld.gov.au/__data/assets/file/0020/83522/lutwyche-aq-2011.csv