Arundel (Gold Coast) 2011 hourly air quality...
Period of operation: 1 January to 31 December 2011
Site location: Latitude: -27.9441; Longitude: 153.3656
AS/NZS 3580.1.1:2007 site classification: Neighbourhood
AS/NZS 3580.1.1:2007 compliance (pollutants): Complies with the exception of the following:
- Three-story building within 20 metres SW of the monitoring site
- Trees above height of inlet within 20 metres W of the monitoring site
AS/NZS 3580.14—2011 compliance (meteorology): Complies with the exception of the following:
- Located on northern side of slope below a ridge running east-west
- Three-story building within 20 metres SW of the monitoring site
- Trees within 20 metres W of the monitoring site
- Temperature and relative humidity sensors located at a height of 10 metres above ground level
- Monitoring shelter located on paved area
Wind: Ultrasonic sensor
- Height above ground level: 10 metres
- The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.
Temperature: Capacitive ceramic sensor
- Height above ground level: 10 metres
Relative humidity: Capacitive thin film polymer sensor
- Height above ground level: 10 metres
Rainfall: Vaisala RAINCAP® precipitation sensor
- Height above ground level: 10 metres
Barometric pressure: Capacitive silicon sensor
- Height above ground level: 10 metres
Ozone: UV absorption analyser operated in accordance with AS/NZS 3580.6.1—2011
- Instrument output offset and/or scaled based on calibration and daily zero/span response data
Oxides of nitrogen: Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1—2011
- Instrument output offset and/or scaled based on calibration and daily zero/span response data
PM10 / PM2.5: Dichotomous Tapered Element Oscillating Balance (TEOM) fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13—2013
- The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter.
- Reported concentrations are uncorrected instrument output values.
- Negative hourly PM10 / PM2.5 concentrations down to -5 µg/m3 resulting from instrument noise at low particle concentrations are reported.
Source
This data file or API can be downloaded from:
https://data.des.qld.gov.au/__data/assets/file/0023/83327/arundel-aq-2011.csvResources
There are no views created for this resource yet.
Data Dictionary
Additional Information
Field | Value |
---|---|
Data last updated | April 2, 2025 |
Metadata last updated | May 5, 2025 |
Format | CSV |
License | cc-by-4 |
Ckan url | https://www.data.qld.gov.au |
Datastore active | True |
Datastore contains all records of source file | True |
Has views | False |
Hash | 5e78bcae6371cf652e980e1ef54ddb3b |
Id | b54227d7-b7d8-4aff-a03d-b533a3473597 |
Ignore hash | False |
Mimetype | text/csv |
Original url | https://data.des.qld.gov.au/__data/assets/file/0023/83327/arundel-aq-2011.csv |
Package id | 94ae85af-a62b-4ae4-a86b-631fb9cc4af5 |
Position | 1 |
Resource id | b54227d7-b7d8-4aff-a03d-b533a3473597 |
Resource type | file |
State | active |
Task created | 2025-04-02 07:13:55.365857 |
Zip extract | False |
Size | Unknown |
ID | b54227d7-b7d8-4aff-a03d-b533a3473597 |
Harvested | True |
Package ID | 94ae85af-a62b-4ae4-a86b-631fb9cc4af5 |
State | active |