Moranbah (Moranbah) 2011 hourly air quality...

Air Quality Monitoring - 2011

Created 05/05/2025

Updated 05/05/2025

Period of operation: 10 March (site established) to 31 December 2011
Site location: Latitude: -21.9995; Longitude: 148.0713
AS/NZS 3580.1.1:2007 site classification: Neighbourhood
AS/NZS 3580.1.1:2007 compliance (pollutants): Complies fully
AS/NZS 3580.14—2011 compliance (meteorology): Complies fully
Wind: Ultrasonic sensor

  • Height above ground level: 10 metres
  • The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +8 degrees to the sensor output value.

Temperature: Capacitive ceramic sensor

  • Sensor mounted in non-aspirated radiation shield – under still conditions reported temperature can be higher than actual

PM10: Tapered Element Oscillating Balance (TEOM) operated in accordance with AS 3580.9.8—2001

  • Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter
  • Instrument output values are adjusted in accordance with US EPA equivalence designation method EQPM-1090-079 requirements (scaled by 1.03, offset by +3.0)
  • After adjustment, negative hourly PM10 concentrations less than -0.5 µg/m3 are removed and concentrations between -0.5 µg/m3 and 0.0 µg/m3 are set to 0.0 µg/m3

Source

This data file or API can be downloaded from:

https://data.des.qld.gov.au/__data/assets/file/0027/83574/moranbah-aq-2011.csv